Instrumentation
Instrumentation
THE LS INSTRUMENTATION ADVANTAGE:
LS Cable & System USA EZ-RFTM Reduced Friction coating is water-based, colorless, non-staining and contains no VOCs. Choose it for any LS Cable & System USA product we offer. Cable with this silicone-free dry lubricant arrives pre-lubricated, replaces messy field-applied lubricants, offers additional weather- and UV-resistance, and reduces friction up to 85%*. EZ-RF allows you to run cable and wire faster and get more from every pull and push, and lower project costs.
We stand behind our products with a 100% satisfaction guarantee. LS Group has executed projects in 50 countries in America, Asia and the Middle East. Our access to the global LS network means if we don’t have what you need, we can get it. LS group’s full line-up of energy distribution products guarantees an optimized solution for each project. Trust our products have been engineered to last and will perform as expected — with a warranty that backs it up.
Series A3PP
The PVC/PVC, 300V Type PLTC/ITC Cables consist of fully annealed bare copper, Class B stranded conductors (in pairs or triads), covered with Polyvinyl Chloride (PVC) insulation, overall shielded or individually and overall shielded and black PVC jacket. These cables are used in control systems, audio, intercom, alarm circuits and energy management.
Applications
- In free air, ducts, cable trays, conduit, raceways and direct burial
- Approved for Class I Div. 2 industrial hazardous locations per NEC
Series A6NP
The PVC/Nylon/PVC, 600V Instrumentation, Type TC-ER and Direct Burial Cables consist of fully annealed bare copper Class B stranded conductors (in pairs or triads), covered with Polyvinyl Chloride (PVC) and clear Nylon insulation, overall shielded or individually and overall shielded and black PVC jacket. These cables are used in control systems, audio, intercom, alarm circuits and energy management.
Applications
- In free air, ducts, cable trays, conduit, raceways and direct burial
- Approved for Class I, Div. 2 industrial hazardous locations per NEC
- Used as a non-power-limited fire alarm circuit cable (NPLF) per NEC Article 760
- Permitted for Exposed Run (ER) used in accordance with NEC for 3 or more conductors; two conductors without a ground wire are Type TC only
Series A6XP
The XLPE/PVC, 600V Instrumentation, Type TC-ER and Direct Burial Cables consist of fully annealed bare copper Class B stranded conductors (in pairs or triads), covered with Cross-linked Polyethylene (XLPE) insulation, overall shielded or individually and overall shielded and black PVC jacket. These cables are used in control systems, audio, intercom, alarm circuits and energy management.
Applications
- In free air, ducts, cable trays, conduit, raceways and direct burial
- Approved for Class I, Div. 2 industrial hazardous locations per NEC
- Permitted for Exposed Run (ER) used in accordance with NEC for 3 or more conductors; two conductors without a ground wire are Type TC only